Water Level Master Tank | See Options |
Water Supply | Up to 4.7 GPM @ 40 PSI |
Water Pressure | 125 PSI Max |
Proportioner(s) | Not Included |
Requirements
Water Level Master Tank | See Options |
Water Supply | Up to 4.7 GPM @ 40 PSI |
Water Pressure | 125 PSI Max |
Proportioner(s) | Not Included |
Overview
The Flow-Thru Water Level Master™ is a float valve system that regulates the flow of water to a low volume proportioner (not included). When the solution in the Level Master Tank (sold separately) drops below a pre-set level, the primary float valve opens to allow water to flow through to the proportioner. The proportioner dilutes concentrated chemical and dispenses the diluted solution into the Level Master Tank. This diluted solution can then be drawn into a second proportioner which dilutes it further and dispenses an ultra-lean solution. The system cycles continuously and a secondary fail-safe float prevents overfilling.
Safety & Operational Precautions
To Install (refer to diagram on next page)
Backflow prevention: Follow all local codes for preventing backflow into the water supply before installing / operating equipment.
To Operate
NOTE: The fill level and fail-safe shutoff level are pre-determined by the length of the "push rods" attached to the floats, which are intended to be used as provided. If necessary, floats can be lowered 1/2" by partially unscrewing them from the push rods.
Secondary Fail-Safe Valve Reset Procedure
Troubleshooting Guide |
---|
Problem | Possible Cause / Solution | |
---|---|---|
Startup | Maintenance | |
A) Proportioner will not draw chemical. B) Dilution too strong. C) Dilution too weak. D) Primary float will not activate (does not fill) E) Primary float valve will not turn off (overfills or triggers secondary fail-safe float valve on double-float models) NOTE: This guide is for Water Level Masters used with Low Flow Proportioners | 1, 4, 5 2 3, 4, 5 7 6, 7 |
8, 9, 10, 11 8, 9, 10, 11 12, 13, 14, 15, 16 12, 13, 14, 15, 16 |
Possible Cause / Solution | |
---|---|
Startup | Maintenance |
|
|
PREVENTIVE MAINTENANCE: When the unit will be out of service for extended periods, place chemical tube(s) in water and flush the chemical out of the unit to help prevent chemical from drying out and causing build-up. Periodically check and clean chemical strainer and replace if missing. |